Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Applications | 2017 | Thermo Fisher ScientificInstrumentation
HPLC
Industries
Food & Agriculture
Manufacturer
Thermo Fisher Scientific

Importance of the topic


Water-soluble vitamins are critical for human health and must be accurately quantified in fortified beverages to ensure safety and label compliance.

Objectives and study overview


The study demonstrates a rapid UHPLC method using Thermo Scientific Acclaim PolarAdvantage II column and Vanquish Flex Binary system for simultaneous analysis of seven water-soluble vitamins in sports drinks with high precision, resolution, and recovery.

Methodology and instrumentation


  • Instrumentation: Vanquish Flex Binary UHPLC system with Binary Pump F, System Base, Split Sampler FT, Column Compartment H, Active Pre-heater, Diode Array Detector HL, LightPipe Flow Cell (2 μL, 10 mm), Virtuoso vial identification system.
  • Column: Acclaim PolarAdvantage II PA2 (100 mm × 3 mm, 2.2 μm).
  • Mobile phases: 0.015% formic acid in water (A) and 20:80 methanol/acetonitrile (B); gradient from 100% A to 45% B in 6 minutes, flow rate 0.5 mL/min, column temperature 50 °C.
  • Detection: UV at 210 nm.
  • Sample preparation: beverages degassed, diluted 1:1 with mobile phase A, filtered, spiked with mixed vitamin standard; calibration standards prepared in mobile phase A.


Key results and discussion


  • Separation: Baseline resolution of seven vitamins achieved in approximately 6 minutes.
  • Precision: Retention time RSD ≤0.27% and peak area RSD ≤1.82% for all compounds.
  • Linearity: Calibration curves with R2 between 0.9953 and 0.9983 over relevant concentration ranges.
  • Recovery: Spiked recoveries ≥80% in three sports drink matrices, indicating minimal matrix interference.
  • Quantification: Measured vitamin concentrations closely matched product label values; vitamin B12 was below the lower limit of quantification in all samples.


Benefits and practical applications


The method offers rapid, sensitive, and reproducible analysis for quality control of vitamin-fortified beverages, supporting regulatory compliance and product development in the food and beverage industry.

Future trends and applications


Advances may include coupling UHPLC to mass spectrometry for enhanced selectivity, high-throughput automation, expansion to diverse matrices, method miniaturization, and integration into online process monitoring for real-time nutrient profiling.

Conclusion


The combination of the Acclaim PolarAdvantage II column and Vanquish Flex Binary system provides a fast and reliable UHPLC method for high-throughput screening of water-soluble vitamins in sports beverages with excellent performance metrics.

Instrumentation


  • Thermo Scientific Vanquish Flex Binary UHPLC system (Binary Pump F, System Base, Split Sampler FT, Column Compartment H, Active Pre-heater, Diode Array Detector HL)
  • Thermo Scientific Acclaim PolarAdvantage II (PA2) column, 100 mm × 3 mm, 2.2 μm
  • LightPipe Flow Cell (2 μL, 10 mm)
  • Virtuoso vial identification system


Reference


Bardsley J. Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages. Thermo Fisher Scientific Application Note AN21671, 2017.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC
Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC
Accelerated method development for the separation of water-soluble vitamins by RP-HPLC with UV detection using an empirical approach to predict separation
Simultaneous Determination of Water- and Fat Soluble Vitamins in Tablets and Energy Drinks by Using a Novel UHPLC System