Sample Preparation, LC/MS, LC/MS/MS, LC/QQQ
IndustriesManufacturerWaters
Importance of the topic
Fully automated solid phase extraction (SPE) greatly streamlines LC-MS bioanalytical workflows, eliminating manual bottlenecks, minimizing human error, and improving reproducibility across days, operators, and laboratories.
Objectives and Study Overview
- Demonstrate integration of the Andrew+ Pipetting Robot with the Extraction+ connected device under OneLab software control.
- Evaluate fully automated SPE in both cartridge (1 cc, 3 cc, 6 cc) and 96-well plate (µElution and macro) formats.
- Compare automated performance against manual SPE procedures in terms of recovery, precision, and method transfer ease.
Methodology and Instrumentation Used
- Instrumentation:
- Andrew+ Pipetting Robot with electronic pipettes and labware gripper
- Extraction+ Connected Device (vacuum pump, SPE manifold, collar lifter)
- OneLab Software for method creation and full vacuum pressure control
- LC-MS: ACQUITY UPLC I-Class with Column Manager coupled to Xevo TQ-XS triple quadrupole mass spectrometer
- Analytical conditions: reversed-phase Oasis HLB sorbents, mobile phases of 0.1% formic acid in water/acetonitrile, 35 °C column temperature, ESI+ MRM acquisition
- Sample preparation: 100 ng/mL spiked pharmaceutical mix in water, 4% phosphoric acid pretreatment, three-step SPE (load, wash, elute), followed by dilution and LC-MS/MS analysis
- Programmable vacuum ramps defined in OneLab ensure consistent liquid evacuation and flow control.
Main Results and Discussion
- Automated SPE recoveries matched manual workflows across all formats (1–6 cc cartridges, µElution and macro plates).
- Intra- and inter-batch precision showed mean recoveries of 83–107% with RSDs below 10%, across multiple analysts.
- Pressure profile control delivered reproducible flow rates and uniform eluate volumes.
- OneLab drag-and-drop protocol design simplified method setup and facilitated seamless transfer between instruments and labs.
Benefits and Practical Applications
- Walk-away SPE workflow reduces hands-on time and frees analysts for higher-value tasks.
- Flexible compatibility with cartridges, 96-well plates, tubes, vials, and bottles.
- Enhanced reproducibility and transferability via cloud-based protocol sharing.
- Scalable throughput for bioanalytical QC/QA, research, and routine laboratory operations.
Future Trends and Potential Applications
- Extension to diverse SPE sorbent chemistries and multidimensional sample preparation strategies.
- Integration with LIMS for fully automated data and sample tracking workflows.
- Adoption in clinical diagnostics, environmental monitoring, and forensic analysis for high-throughput cleanup.
- Implementation of AI-guided optimization of pressure profiles and solvent gradients for novel analyte classes.
Conclusion
The combined Andrew+ Pipetting Robot and Extraction+ connected device, under OneLab control, deliver a robust, fully automated SPE solution. Performance equivalence to manual methods was confirmed, with significant improvements in efficiency, reproducibility, and protocol portability across laboratories.
References
- Waters Corporation. Oasis SPE Wall Chart, p/n 720001981.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.