Significance of the Topic


Comprehensive comparison of innovator and biosimilar monoclonal antibodies (mAbs) is critical for regulatory approval and quality assurance. Characterizing glycoforms and charge variants at intact and subunit levels ensures that structural and post-translational modifications fall within acceptable similarity thresholds, safeguarding efficacy and safety in therapeutic applications.

Objectives and Study Overview


This study aimed to establish a robust, streamlined workflow for biosimilar comparability assessment of infliximab (Remicade®) and three biosimilars (Inflectra®, Avsola®, Renflexis®). Key goals included:
  • Developing denatured reversed-phase LC-MS (RPLC-MS) and native ion exchange LC-MS (IEX-MS) assays on the Xevo G3 QTof platform
  • Comparing intact mAb and IdeS-digested subunit profiles for N-glycoforms and C-terminal lysine variants
  • Demonstrating confident assignment at low abundance levels (<5% for intact, ~1% for subunit)

Methodology and Instrumentation


Analyses were performed in triplicate at intact and subunit levels. Experimental design:
  • Sample preparation: Denatured intact mAbs and IdeS digests yielding (Fc)2 and (Fd+LC) subunits
  • RPLC conditions: ACQUITY Premier BEH C4 column with inline UV 280 nm detection
  • IEX conditions: BioResolve SCX mAb column under native buffer conditions
  • Mass spectrometry: Waters Xevo G3 QTof platform controlled via UNIFI software and waters_connect informatics
  • Data processing: UNIFI applications for INTACT and UNIFI for subunit quantitation and deconvolution (MaxEnt1)

Main Results and Discussion


Intact RPLC-MS profiles revealed distinct mass shifts corresponding to N-glycoform variants and C-terminal lysine truncation. Mirror plots of deconvoluted spectra enabled confident assignment of major glycoforms (FA2/FA2G1, FA2G1/FA2G2) and minor forms down to 5% relative abundance. Native IEX-MS separated charge variants, confirming three C-terminal lysine species in Remicade and biosimilars through MaxEnt1 deconvolution and post-treatment with carboxypeptidase B.
Subunit RPLC-MS provided enhanced sensitivity, quantifying Fc N-glycoforms at ~1% levels and detecting immunogenic glycans (NeuGc, α-Gal). IEX-MS subunit analysis of (Fd+LC)2 fragments distinguished acidic species consistent with deamidation or conformational variants, supporting intact findings.

Benefits and Practical Applications


The combined intact and subunit workflows offer:
  • High sensitivity and resolution for minor variant detection
  • Streamlined data acquisition and processing via a unified informatics platform
  • Applicable comparability strategy for regulatory submissions and quality control in biopharmaceutical development

Future Trends and Opportunities


Advances may include integration of higher-resolution instruments, automated data interpretation with machine learning, and expansion to real-time release testing. Further, application to other therapeutic proteins and multi-attribute methods will enhance throughput and confidence in biotherapeutic comparability assessments.

Conclusion


The Xevo G3 QTof-based RPLC-MS and IEX-MS workflows successfully characterized key structural attributes of infliximab and its biosimilars, detecting glycoform and charge variant differences at low abundance. The approach supports robust comparability assessment, meeting regulatory expectations for biosimilarity evaluation.

References


No formal references were provided in the source document, beyond trademark acknowledgments for Waters and biopharma products.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

A Robust Workflow for Biosimilar Comparability Assessment via Intact and Subunit RPLC-MS and Native IEX-MS with a Prototype Benchtop QTOF
Comprehensive Biosimilar Comparability Assessment via Intact and Subunit RP-MS and IEX-UV-MS Using the Xevo™ G3 QTof System
Applying Peptide Mapping and Multi- Attribute Method (MAM) Workflow for Biosimilar mAb Drug Products Comparison on the Xevo™ G3 QTof Platform
Multi-Attribute Methods for Biopharmaceutical Analysis