NIR Spectroscopy
IndustriesEnergy & Chemicals
ManufacturerMetrohm
Significance of the Topic
The chemical composition of alcohol mixtures used in antiseptic products is a critical quality parameter.
Rapid, nondestructive, real-time analytical techniques help ensure product efficacy and regulatory compliance.
Aims and Overview of the Study
This work demonstrates a fast method to quantify ethanol and isopropanol in binary mixtures using visible near-infrared spectroscopy (VIS-NIRS).
The goal is to enable simultaneous determination of both alcohols in under a minute, suitable for routine quality control.
Methodology and Instrumentation
44 custom liquid samples with ethanol/isopropanol ratios from 0 to 100% were prepared.
Spectra were acquired in transmission mode over 400–2500 nm at a controlled temperature of 30 °C.
Chemometric modeling employed second-derivative pretreatment and partial least squares (PLS) regression.
Calibration used 33 samples, and validation used an independent set of 11 samples.
Used Instrumentation
- Metrohm NIRS XDS RapidLiquid Analyzer (Part No. 2.921.1410): spectral range 400–2500 nm
- 8 mm disposable glass vials (Part No. 6.7402.000)
- Vision Air 2.0 Complete software (Part No. 6.6072.208) for data acquisition and method development
Main Results and Discussion
Excellent correlation between VIS-NIR predictions and reference values was achieved for both analytes.
- Ethanol model: R² = 0.9998; SEC = 0.34 %; SECV = 0.37 %; SEP = 0.44 %
- Isopropanol model: R² = 0.9998; SEC = 0.38 %; SECV = 0.41 %; SEP = 0.45 %
Spectral features near 1460 nm (first O-H overtone) and around 2100 nm (O-H combination band) varied systematically with concentration.
Second-derivative spectra compensated for baseline shifts and improved model robustness.
Benefits and Practical Applications
- Analysis time under one minute per sample
- No chemical reagents or sample preparation required
- Simultaneous quantification of multiple alcohols in a single measurement
- Real-time feedback for manufacturing and quality assurance
Future Trends and Possibilities
- Implementation of inline VIS-NIR sensors for continuous process monitoring
- Expansion of methods to additional formulation components (moisture, additives, colorants)
- Development of advanced multivariate algorithms for complex mixtures
- Integration with Industry 4.0 data systems for automated QC workflows
Conclusion
Visible near-infrared spectroscopy using the Metrohm XDS RapidLiquid Analyzer provides a reliable, rapid, and nondestructive approach to quantify ethanol and isopropanol in antiseptic formulations.
The validated chemometric models deliver high accuracy and precision, supporting efficient quality control in industrial settings.
References
- NIR Application Note NIR-061, Metrohm AG, Version 1, July 2018
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.