Sample Preparation, Consumables, LC/MS, LC/MS/MS, LC columns, LC/QQQ
IndustriesClinical Research
ManufacturerThermo Fisher Scientific
Importance of the Topic
Urinary steroid profiling is vital in clinical diagnostics, endocrinology and anti-doping analysis. Rapid, reliable quantification of corticosteroids such as hydrocortisone, cortisone, corticosterone and 11-α hydroxyprogesterone helps monitor hormone therapy, detect metabolic disorders and enforce fair sports practices.
Objectives and Study Overview
This study demonstrates a streamlined workflow combining Thermo Scientific SOLA SPE 96-well plates for sample cleanup with fast LC-MS/MS separation on an Accucore RP-MS core-shell HPLC column. The aim is to achieve high throughput, excellent reproducibility and low solvent consumption while maintaining sensitivity and robustness.
Methodology and Instrumentation
Sample Preparation
- Matrix: human urine spiked with internal standards for corticosterone and 11-α hydroxyprogesterone
- SPE: SOLA 96-well plate conditioned with methanol and water, sample application, wash with 20:80 methanol/water and elution in methanol
- Evaporation: nitrogen drying, reconstitution in water
Chromatography
- Column: Accucore RP-MS 2.6 µm, 100×2.1 mm at 25 °C
- Mobile phases: A = water + 0.1% formic acid, B = acetonitrile + 0.1% formic acid
- Gradient: 25% B to 75% B in 4 min, total run time 6 min, flow 0.6 mL/min, injection volume 2.5 µL
Mass Spectrometry
- Instrument: TSQ Vantage with HESI source, positive mode
- Key settings: spray voltage 3000 V, vaporizer and capillary at 300 °C, collision pressure 1.5 mTorr
Main Results and Discussion
The four steroids were baseline-separated in under 3 minutes. Calibration curves from 1 to 1000 ng/mL showed linearity (r2 ≥ 0.9937). Endogenous levels in urine:
- Hydrocortisone: 17.3 ng/mL (RSD 11.1%)
- Cortisone: 55.6 ng/mL (RSD 7.4%)
Benefits and Practical Applications
- High throughput SPE reduces processing time and solvent use
- Core-shell column delivers sharp peaks, low backpressure and fast runs
- Robust method suitable for routine clinical or anti-doping laboratories
Future Trends and Opportunities
Advancements may include integration of automated SPE platforms, expansion to broader steroid panels, coupling with high-resolution mass spectrometry for untargeted profiling and further miniaturization to reduce cost and sample volume.
Conclusion
The combination of SOLA SPE well plates and Accucore RP-MS columns provides a fast, reproducible and sensitive approach for quantitative analysis of urinary steroids. This workflow meets the demands of high-throughput clinical and bioanalytical settings without sacrificing data quality.
Reference
Thermo Fisher Scientific. Application Note ANCCSSOLASTDS: LC-MS/MS Method for the Determination of Steroids from Urine Using SOLA and Core Enhanced Technology Accucore HPLC Column (2011).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.