Quantitative Analysis of Mevalonate in Plasma Using LC-MS/MS

Applications | 2016 | Thermo Fisher ScientificInstrumentation
LC/MS, LC/MS/MS, LC/IT
Industries
Clinical Research
Manufacturer
Thermo Fisher Scientific

Quantitative Analysis of Mevalonate in Plasma Using LC-MS/MS


Význam tématu


Cholesterol biosynthesis is a vital metabolic pathway, with mevalonate serving as the key intermediate. Measuring plasmatic mevalonate provides an indirect assessment of in vivo cholesterol production and supports evaluation of lipid-lowering therapies such as statins in clinical research and quality-control environments.


Cíle a přehled studie


This work aimed to establish a rapid, reliable, and sensitive liquid chromatography–tandem mass spectrometry assay for quantifying mevalonate in human plasma. Emphasis was placed on streamlined sample preparation and a short analysis time compatible with high-throughput pharmacological studies.


Použitá metodika a instrumentace


  • Sample preparation: 500 µL plasma spiked with 20 ng mevalonate-D7, acidified to convert mevalonate into its lactone form, followed by solid-phase extraction (SPE). Dried extracts were reconstituted in 0.2% ammonium hydroxide and 10 µL injected.
  • Chromatography: Thermo Scientific Surveyor autosampler and pump with BioBasic AX column (150 × 2.1 mm, 5 µm). Gradient elution using 10 mM ammonium formate (pH 8) and acetonitrile at 200 µL/min.
  • Mass spectrometry: Thermo LTQ linear ion trap with electrospray ionization in negative mode. Monitored transitions: m/z 147→59 for mevalonate and m/z 154→59 for mevalonate-D7. Key settings: spray voltage 2 kV, sheath/auxiliary gas nitrogen, ion transfer tube at 300 °C, collision energy 30%.

Hlavní výsledky a diskuse


  • Linearity: Calibration range 2.5–250 ng/mL with correlation coefficient r2 > 0.9993 (1/x weighting).
  • Precision: Intraday coefficient of variation between 0.5% and 4% (n=3).
  • Sensitivity: Limit of detection 2 pg; limit of quantification 2.5 ng/mL.
  • Run time: Total analysis completed in 10 minutes, analyte elution between 3.0 and 6.5 minutes.
  • Validation: Successful quantification of mevalonate in a healthy volunteer sample (24 ng/mL).

Přínosy a praktické využití metody


  • High throughput capability suitable for pharmacokinetic and clinical investigations.
  • SPE cleanup reduces matrix effects and simplifies sample handling.
  • Use of stable isotope internal standard ensures accurate quantification across diverse plasma matrices.

Budoucí trendy a možnosti využití


Future developments may include automated sample preparation workflows, miniaturized LC-MS platforms for bedside monitoring, and expanded multiplex assays profiling additional cholesterol pathway intermediates. Coupling with high-resolution mass spectrometry could further enhance specificity and broaden metabolite coverage.


Závěr


A robust, 10-minute LC-MS/MS method has been validated for sensitive and precise quantification of mevalonate in plasma. This protocol offers a valuable tool for clinical pharmacology and research into cholesterol metabolism.


Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Clinical research and forensic toxicology - Application Compendium
Mass Spectrometry Applications for Environmental Analysis
Mass Spectrometry Applications for Environmental Analysis
Mass Spectrometry Applications for Environmental Analysis
2014|Thermo Fisher Scientific|ApplicationsGuides
Mass Spectrometry Applications for Environmental Analysis