LC/MS, LC/MS/MS, LC/QQQ
IndustriesEnvironmental
ManufacturerThermo Fisher Scientific
Significance of the topic
The occurrence of pharmaceuticals, personal care products, pesticides and endocrine disruptors in water resources is an emerging environmental concern. These compounds enter surface and drinking waters via human and animal waste, agricultural runoff and improper disposal. Even at ultra-trace levels (ng/L), they can affect aquatic ecosystems and pose potential risks to human health. Comprehensive analytical methods are required to monitor a wide range of organic contaminants and guide water treatment decisions.
Objectives and study overview
This work aimed to develop a streamlined method combining solid phase extraction (SPE) with atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry (APCI-LC-MS/MS) for simultaneous quantification of diverse organic wastewater contaminants at low ng/L concentrations. Fourteen representative compounds spanning pharmaceuticals, personal care products, hormones and pesticides were targeted. The method was applied to samples collected from the Mille Iles, des Prairies and St. Lawrence rivers in the Montreal region to assess contaminant occurrence and concentration variations.
Methodology
The analytical workflow included:
- Collection of triplicate 1 L samples from each river, acidified with sulfuric acid and stored at 4 °C.
- Filtration through 0.7 µm and 0.45 µm membranes prior to extraction within 24 hours.
- SPE using 200 mg C18 cartridges: conditioning with methanol and water, sample loading, washing and nitrogen drying.
- Elution with methyl tert-butyl ether/methanol mixtures, evaporation under nitrogen and reconstitution in aqueous formic acid/methanol containing isotopically labeled standards.
Instrumentation
Chromatographic separation was performed on a Thermo Scientific Surveyor HPLC system with a Hypersil GOLD C18 column (50×2.1 mm, 3 µm) at 30 °C. A TSQ Quantum Ultra triple quadrupole mass spectrometer equipped with an APCI source operated in positive and negative modes. Key parameters included a vaporizer temperature of 500 °C, capillary temperature of 250 °C, and selective reaction monitoring transitions for each analyte.
Key results and discussion
The method demonstrated excellent performance:
- Limits of detection ranged from 0.03 to 2 ng/L in surface water.
- Recoveries between 72 % and 94 % with RSD values of 3–11 % across compounds.
- Minimal matrix effects (< 13 % suppression or enhancement) in real samples.
- Good linearity (R2 > 0.99) up to 100 ng/L.
Benefits and practical applications of the method
This approach offers several advantages:
- A single SPE-LC-MS/MS workflow for multiple compound classes reduces time and resource requirements.
- APCI ionization enhances sensitivity for low-polarity analytes like steroids and reduces matrix interferences.
- Detection capabilities at sub-ng/L levels support compliance monitoring and risk assessment.
- Method adaptability allows integration into routine environmental monitoring programs.
Future trends and potential applications
Ongoing and future developments may include:
- Integration of high-resolution mass spectrometry for non-target screening of unknown emerging contaminants.
- Automation of sample preparation and data processing to increase throughput.
- Expansion of analyte scope to include transformation products and novel personal care ingredients.
- Real-time monitoring tools and remote sensing to support rapid water quality assessments.
- Data integration with modelling platforms to predict contaminant fate and guide treatment strategies.
Conclusion
The developed APCI-LC-MS/MS method provides a robust, sensitive and efficient solution for simultaneous trace analysis of diverse organic pollutants in surface waters. Its successful application to Montreal watershed samples underscores widespread occurrence of pharmaceuticals, personal care products, pesticides and hormones, informing water management decisions and treatment upgrades.
Reference
- Ternes TA, Joss A, editors. Human Pharmaceuticals, Hormones and Fragrances: The Challenge of Micropollutants in Urban Water Management. IWA Publishing; 2006.
- Kortenkamp A. Environmental Health Perspectives. 2007;115(Suppl 1):1–42.
- Hao C, Lissemore L, Nguyen B, Kleywegt S, Yang P, Solomon KR. Anal Bioanal Chem. 2006;384:505–513.
- Metcalfe CD, Mia X-S, Hua W, Letcher R, Servos M. In: Kummerer K, editor. Pharmaceuticals in the Environment: Sources, Fate, Effects and Risks. Springer; 2004:67–87.
- Gagné F, Blaise C, André C. Ecotoxicology and Environmental Safety. 2006;64:329–336.
- Segura PA, Garcia-AC A, Lajeunesse A, Ghosh D, Gagnon C, Sauvé S. J Environ Monit. 2007;9:307–313.
- Trenholm RA, Vanderford BJ, Holady JC, Rexing DJ, Snyder SA. Chemosphere. 2006;65(11):1990–1998.
- Zwiener C, Frimmel FH. Anal Bioanal Chem. 2004;378:862–874.
- Ternes TA. Trends Anal Chem. 2001;20(8):419–434.
- Souverain S, Rudaz S, Venthey JL. J Chromatogr A. 2004;1058:61–66.
- Vanderford BJ, Pearson RA, Rexing DJ, Snyder SA. Anal Chem. 2003;75:6265–6274.
- Schilling JB, Cepa SP, Menacherry SD, Barda LT, Heard BM, Stockwell BL. Anal Chem. 1996;68:1905–1912.
- Li LYT, Campbell DA, Bennett PK, Henion JD. Anal Chem. 1996;68:3397–3403.
- Reemtsa T. Trends Anal Chem. 2001;20:533–542.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.