High Speed Analysis of Ibuprofen and Ibuprofen Related Compound

Applications | 2021 | ShimadzuInstrumentation
Consumables, HPLC, LC columns
Industries
Pharma & Biopharma
Manufacturer
Shimadzu

Importance of the Topic


Ibuprofen is a non-steroidal anti-inflammatory drug (NSAID) extensively used for its analgesic, anti-inflammatory and antipyretic effects. Rapid and reliable analysis of ibuprofen and related impurities is essential for quality control in pharmaceutical manufacturing and regulatory compliance. High-speed methods increase laboratory throughput and reduce analysis time without sacrificing accuracy.

Aims and Study Overview


This application note describes the development of a fast reversed-phase liquid chromatographic method for the simultaneous determination of ibuprofen, an internal standard (valerophenone), and a related impurity (4-isobutylacetophenone). The study focuses on achieving separation in under 10 minutes using Shimadzu’s Shim-pack GIST C18-HP column and Nexera Dual Injection System.

Methodology and Instrumentation


The method employs a high-efficiency C18 column and optimized mobile phase to achieve baseline resolution in a short run time.
  • System: Nexera Dual Injection System
  • Column: Shim-pack GIST C18-HP (75 mm × 3.0 mm I.D., 3 µm)
  • Mobile phase: A) 1% (w/v) chloroacetic acid in water (pH 3.0); B) acetonitrile; ratio A/B = 1:1
  • Flow rate: 1.0 mL/min
  • Column temperature: 35 °C
  • Injection volume: 1.0 µL
  • Detection: UV at 254 nm (SPD-40 detector)

Main Results and Discussion


The optimized method achieved the following separation within 7 minutes:
  • Peak 1: Ibuprofen eluting at ~2.6 minutes
  • Peak 2: Valerophenone (internal standard) at ~4.0 minutes
  • Peak 3: 4-Isobutylacetophenone at ~5.2 minutes
The chromatogram showed sharp, symmetric peaks with adequate resolution (>1.5) between all analytes. The fast analysis enabled baseline separation of impurity from the main drug peak, satisfying regulatory requirements.

Benefits and Practical Applications


The method offers several practical advantages:
  • High throughput: Reduced run time increases sample capacity
  • Robustness: Stable retention times and peak shapes under routine conditions
  • Sensitivity: UV detection at 254 nm provides reliable quantification
  • Versatility: Applicable to QC laboratories for batch release and stability testing

Future Trends and Possibilities


Future developments may include coupling this method with mass spectrometric detection for enhanced specificity, exploring ultra-high-pressure chromatography (UHPLC) to further reduce analysis time, and applying similar rapid protocols to other NSAIDs or multi-component dosage forms. Integration with automated sample preparation systems could also streamline workflows.

Conclusion


The proposed LC method using the Shim-pack GIST C18-HP column on a Nexera Dual Injection System enables fast, accurate determination of ibuprofen and a key impurity. It meets the demands of modern pharmaceutical quality control by delivering high resolution, short analysis times, and robust performance.

Reference


  • Application News 01-00129 (JP), Shimadzu Corporation, First Edition: Dec. 2021

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Analysis of Coumarin and Cinnamaldehyde
Analysis of Coumarin and Cinnamaldehyde
2021|Shimadzu|Applications
Analysis of Isopropyl methylphenol(IPMP)
Preparative Purification of Ibuprofen and Its Related Substance (Shim-pack UFPLC)
Simultaneous Analysis for Drug Purity Test and Quantitative Assay