EasyPep Sample Preparation Technology for Rapid and Efficient Mass Spectrometry-based Proteomics

Posters | 2020 | Thermo Fisher Scientific | ASMSInstrumentation
Sample Preparation, LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
Industries
Proteomics
Manufacturer
Thermo Fisher Scientific

Significance of the Topic



Advances in mass spectrometry instrumentation have unlocked high-resolution analysis of complex proteomes, yet upstream protein sample preparation remains a bottleneck due to lengthy protocols, variable yields, and low reproducibility. Standardizing and accelerating sample preparation workflows is critical for applications ranging from biomarker discovery to clinical QA/QC and large-scale multi-omics studies.

Objectives and Study Overview



This study introduces two new formats within the Thermo Scientific™ EasyPep™ sample preparation technology:
  • A Maxi kit for large-scale processing (0.5–2 mg protein) tailored to post-translational modification analysis.
  • A 96-well plate format for high-throughput, automated workflows on 10–100 µg protein samples.

The work compares all three EasyPep formats (Mini, Maxi, 96-well) across diverse sample types—including human cell lines, plasma/serum, yeast, E. coli, tissues, and FFPE sections—to assess performance, reproducibility, and compatibility with TMT labeling and phosphopeptide enrichment.

Methodology and Instrumentation Used



Sample Preparation:
  • Cell and tissue lysis in buffer with reduction, alkylation, and Trypsin/Lys-C digestion (under 3–4 hr).
  • Peptide cleanup via Mini/Maxi columns or 96-well filter plates under centrifugation, vacuum, or positive-pressure modes.
  • Optional plasma depletion with Top14 spin columns.
  • Phosphopeptide enrichment using Fe-NTA resins and TMT6plex labeling before or after digestion.

Instrumentation:
  • Thermo Scientific™ Dionex™ UltiMate™ 3000 Nano LC with 50 cm EASY-Spray C18 column.
  • Thermo Scientific™ Q Exactive™ Plus Hybrid Quadrupole-Orbitrap mass spectrometer.
  • Automated handling on Hamilton™ STARlet™ liquid handler for the 96-well format.

Main Results and Discussion



Peptide and Protein Identifications:
  • All formats yielded comparable identifications from HeLa and A549 cells (≈5 200 proteins, >30 000 peptides) within a <4-hr workflow.
  • EasyPep outperformed conventional protocols by 10–20 % more IDs and reduced missed cleavages; TMT labeling efficiency exceeded 99 % with near–zero missed modifications.

Sample-Type Compatibility:
  • High reproducibility (CVs <1 %) across cell lines, plasma/serum (depleted and non-depleted), yeast, bacteria, and fresh/fixed tissues (CVs <5 %).
  • FFPE and fresh-frozen tissues yielded similar identifications (~29 000–31 000 peptides) after xylene/ethanol deparaffinization.

Phosphoproteomics and PTM Analysis:
  • Fe-NTA enrichment post-EasyPep gave >95 % phosphopeptide specificity within 3–5 hr, matching conventional workflows.
  • Maxi format optimized for PTM workflows on milligram-scale inputs.

Benefits and Practical Applications



The EasyPep technology delivers:
  • Rapid, streamlined sample preparation (<4 hr) with standardized protocols.
  • Scalable formats accommodating both low-microgram and milligram inputs.
  • Seamless integration with isobaric labeling and phosphopeptide enrichment for quantitative and PTM studies.
  • Compatibility with automation platforms for high-throughput screening and clinical testing.
  • Consistent high yields and identification rates conducive to biomarker discovery, QA/QC, and drug development pipelines.

Future Trends and Possibilities



As proteomics moves toward larger cohort studies and multi-omics integration, automated and miniaturized workflows will be essential. Potential developments include:
  • Microfluidic implementations to further reduce input and reagent consumption.
  • Enhanced multiplexing strategies using novel isobaric tags beyond TMT6plex.
  • AI-driven protocol optimization to tailor sample prep to unique matrix challenges.
  • Cloud-based data processing integration to link upstream prep metadata with downstream analytics.

Conclusion



Expanding the EasyPep sample preparation portfolio with Maxi and 96-well formats addresses the dual needs of high throughput and large-scale PTM workflows. The standardized chemistry and automation compatibility yield rapid, reproducible, and high-quality proteomic datasets across diverse sample types, positioning EasyPep as a versatile solution for research and clinical proteomics.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Large Scale EasyPep MS Sample Preparation for Phosphopeptide Enrichment Workflows
An Optimized Sample Preparation Method of Formalin-Fixed Paraffin-Embedded Tissues for Mass Spec Applications
An EasyPep Magnetic Solution for Automated Proteomics Sample Preparation
New tools for improved proteomics results
New tools for improved proteomics results
2022|Thermo Fisher Scientific|Brochures and specifications