LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesMetabolomics
ManufacturerThermo Fisher Scientific
Importance of the topic
Metabolomics enables comprehensive profiling of small molecules in biological systems and relies on high-resolution, accurate-mass measurements for confident identification. The benchtop Orbitrap Exploris 240 MS addresses the demand for robust, reproducible data acquisition in diverse metabolomic applications.
Objectives and overview
- Develop and validate metabolomics workflows leveraging the Orbitrap Exploris 240 for reliable quantitation and annotation.
- Demonstrate reproducible sub-ppm mass accuracy and stable signal response over multiple days.
- Employ the AcquireX intelligent acquisition strategy to maximize MS/MS coverage.
Methods and instrumentation
- Liquid chromatography: Thermo Vanquish UHPLC with Hypersil GOLD column (15 cm×2.1 mm, 1.9 μm particle size), 0.3 mL/min gradient (0.1% formic acid in water/methanol), 15 min total run time.
- Mass spectrometry: Orbitrap Exploris 240 operated in full scan (120 000 resolution) and MS/MS (30 000 resolution) modes, H-ESI source (3500 V positive, 3000 V negative), gas flows and temperatures optimized for sensitivity.
- AcquireX Deep Scan workflow for iterative data-dependent acquisition to enrich unique MS/MS spectra.
- Data processing: TraceFinder for targeted quantitation; Compound Discoverer for untargeted profiling, elemental composition and fragmentation matching.
Main results and discussion
- Sustained sub-ppm mass accuracy (<1 ppm) across three instruments over five days.
- Signal response stability with coefficients of variation of 5–10% in positive, negative and polarity-switching modes.
- AcquireX increased MS/MS coverage by over 75%, generating spectra for 1641 compounds vs. 793 in traditional DDA.
- High resolution delivered clear isotope patterns and fine structural details, enabling confident assignment of elemental compositions (e.g., adenosine [M+H]+ m/z 268.10385).
- Extended MS/MS mass range differentiated isomeric metabolites by detecting additional fragment ions.
Benefits and practical applications
- Reliable performance supports large-scale studies, QA/QC workflows and longitudinal experiments.
- Enhanced metabolite and lipid annotation in complex biological matrices.
- Improved discrimination of isobaric and isomeric species enhances data quality and biological interpretation.
Future trends and potential applications
- Integration of AI-driven analytics and automated annotation to accelerate data interpretation.
- Extension of workflows to lipidomics, flux analysis and quality control in clinical research.
- Automation of sample preparation and multiplexed acquisition strategies to increase throughput.
Conclusion
The Orbitrap Exploris 240 benchtop mass spectrometer offers a robust platform for metabolomics, delivering high mass accuracy, reproducible signal response and enhanced MS/MS coverage via AcquireX, thereby facilitating comprehensive and confident metabolome analysis.
Reference
- Schroeder M., Ntai I., Mohring S., Kellmann M., Harder A., Tautenhahn R., Souza A., Huhmer A. Robust Metabolomics Workflows Using a Modified Benchtop Orbitrap Mass Spectrometer. Thermo Fisher Scientific; 2020.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.