Maximize LC-MS throughput
During gradient elution of LC-MS analysis the elution window of
the compounds of interest is often only a fraction of the total run
time limiting the final sample throughput. The Thermo Scientific™
Vanquish™ Duo UHPLC System for Thermo Scientific™ Transcend™
Duo LX-2 can double LC-MS throughput with a multi-channel LC
approach that eliminates wasted time from the application.
• Double throughput without compromising data quality
• Small footprint for optimal bench space utilization
• Improves flexibility by running two different methods simultaneously
• Accelerates Return on Investment with greater MS utilization
Thermo Scientific Vanquish Duo System
for Transcend Duo LX-2
Channel 2
Resulting
MS Signal
Channel 1
Multichannel LC-MS Method
Analytical Gradient
Application 1
Recondi-
tioning
Recondi-
tioning
Analytical Gradient
Application 2
App. 1
Application 1
App. 1
App. 1
App. 1
Analytical Gradient
Application 1
Recondi-
tioning
Analytical Gradient
Application 1
Recondi-
tioning
Analytical Gradient
Application 1
Recondi-
tioning
Analytical Gradient
Application 2
Recondi-
tioning
Analytical Gradient
Application 2
Application 2
Application 1
Application 2
Application 1
Application 2
Application 1
Dual
Sampler
Pump 1
Injector 1
Column 1
Pump 2
Injector 2
Column 2
Valve
MS
The collective
power of
chromatography
Find out more at
thermofisher.com/vanquishduo
©2019 Thermo Fisher Scientific Inc. Analyst Software is trademarked and owned by AB SCIEX. All other rights reserved. All
trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the
capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might
infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are
available in all countries. Please consult your local sales representatives for details.
PS73010-EN 0519S
Thermo Scientific Vanquish Duo UHPLC System for Transcend Duo LX-2
The Transcend Duo LX-2 workflow consists of two
independent LC channels which can independently operate
to run the separation. This combination along with the smart
scheduling capability of Thermo Scientific™ Aria™ MX software
results in doubled throughput without any sacrifice in data
quality, sensitivity or additional bench space.
Aria MX software manages and controls all aspects of
the Transcend system. It is powerful enough to schedule
and manage multiple methods on multiple channels
simultaneously. At the same time, it features an intuitive
graphical method editing, allowing anyone to quickly develop
methods and run batches of samples. Aria software is built
into Thermo Scientific mass spectrometer software such
as Thermo Scientific™ TraceFinder™, and Thermo Scientific™
Xcalibur™ software. It can also communicate and run with
Analyst® software.
Vanquish Flex Duo for
Transcend Duo LX-2
Vanquish Horizon Duo for
Transcend Duo LX-2
Transcend LX-2
Max. Pressure
1000 bar
1500 bar
1000 bar
Autosampler Arms
2
2
1
Injection precision
<0.25%
<0.25%
RSD < 0.5 %
Footprint (w x D)
54 x 62 cm
54 x 62 cm
142 x 82 cm
Sample Capacity
4 Plates
4 Plates
6 Plates