Fast Analysis of Terbutaline in Pharmaceuticals by CE-MS/MS

Applications | 2016 | Agilent TechnologiesInstrumentation
LC/MS, LC/MS/MS, LC/QQQ, Capillary electrophoresis
Industries
Clinical Research
Manufacturer
Agilent Technologies

Significance of the Topic


Terbutaline is a β2-adrenergic agonist used in asthma relief and to delay preterm labor. Reliable quantification of terbutaline in diverse pharmaceutical forms such as syrups, inhalants, and injectables is critical for quality control, patient safety, and regulatory compliance.

Objectives and Study Overview


This work aimed to develop and validate a rapid capillary electrophoresis–tandem mass spectrometry (CE-MS/MS) method for determining terbutaline in pharmaceutical syrups. The method was benchmarked against the British Pharmacopoeia’s HPLC protocol to assess accuracy, sensitivity, and speed.

Methodology and Instrumentation


Sample Preparation:
  • Syrup samples homogenized and diluted 1:100 in background electrolyte (BGE).
  • Filtration through 0.2-µm PVDF/PP cartridges.
CE-MS/MS Conditions:
  • Background electrolyte: 25 mM propionic acid + 25 mM ammonium hydroxide (pH 7.0).
  • Capillary: fused silica, 50 µm i.d., 60 cm length, 25 kV, 25 °C.
  • Injection: hydrodynamic, 50 mbar for 10 s.
  • Sheath liquid: BGE diluted 1:4 in H2O/methanol (1:1), 5 µL/min.
  • MS in positive ESI MRM mode, two transitions (m/z 226→152 for quantification, 226→107 for confirmation).
Used Instrumentation:
  • Agilent 7100 CE system
  • Agilent 6430 triple quadrupole mass spectrometer

Main Results and Discussion


  • Migration time for terbutaline: ~3.4 min, total run under 5 min.
  • Linearity over 0.05–50 µg/mL, correlation coefficient R² > 0.999.
  • Limit of detection: 0.01 µg/mL; limit of quantification: 0.03 µg/mL.
  • Analysis of two commercial syrup samples yielded 299.0–300.2 µg/mL by CE-MS/MS vs. 300.0–301.0 µg/mL by HPLC, confirming accuracy and precision.

Advantages and Practical Applications


The CE-MS/MS protocol offers rapid analysis, high sensitivity, minimal sample and reagent consumption, and simplified sample preparation without extensive cleanup. Its specificity and quantitative performance make it suitable for routine QC in pharmaceutical development and manufacturing laboratories.

Future Trends and Potential Applications


  • Extension to other β-adrenergic drugs and combination formulations.
  • Miniaturization and green CE approaches to further reduce solvent use.
  • Integration with high-throughput workflows and automated sample handling.
  • Application in bioanalytical and clinical pharmacokinetic studies.

Conclusion


The developed CE-MS/MS method provides a fast, sensitive, and accurate alternative to conventional HPLC for terbutaline quantification in pharmaceutical syrups. Its robustness and low resource consumption support broader adoption in quality control and research settings.

References


  1. Sharma N. et al. RSC Advances 2015, 5, 39003–39011.
  2. Lee D. C. Annals of Emergency Medicine 1995, 26, 107–108.
  3. Hashem H. A. et al. J. AOAC Int. 2012, 95, 1412–1417.
  4. Zhou T. et al. Biomed. Chromatogr. 2014, 28, 994–1002.
  5. Zhou S. et al. Electrophoresis 2008, 29, 2321–2329.
  6. British Pharmacopoeia, Vol. 3, MHRA, UK, 2009, pp. 3002–3003.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Determination of Sulfonamides in Commercial Veterinary Formulations by CE-MS/MS
Determination of B-vitamins in Energy Drinks by CE/MS/MS
Determination of B-vitamins in Energy Drinks by CE/MS/MS
2018|Agilent Technologies|Applications
Determination of Benzodiazepines in Urine by CE-MS/MS
Determination of Benzodiazepines in Urine by CE-MS/MS
2017|Agilent Technologies|Applications
Determination of Malic Acid and Lactic Acid in Wine by CE-MS/MS