Simultaneous Analysis of Water-soluble and Fat-soluble Vitamins in Fish by Novel SFC-MS/MS Method

Posters | 2017 | ShimadzuInstrumentation
LC/MS, LC/MS/MS, LC/QQQ, SFC
Industries
Food & Agriculture
Manufacturer
Shimadzu

Importance of the Topic


The analysis of water- and fat-soluble vitamins in fish is critical for nutritional profiling, food quality control, and regulatory compliance. Fish are a major dietary source of essential vitamins, and rapid, accurate determination ensures consumer safety, supports nutritional studies, and informs aquaculture practices.

Study Objectives and Overview


This study aimed to develop a novel supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS) method for the simultaneous quantitation of 17 vitamins (eight water-soluble and nine fat-soluble) in fish samples. By employing a single chromatographic system, it overcomes limitations of traditional dual-method approaches.

Methodology


  • Sample preparation: Separate extraction workflows for water-soluble vitamins (WSV) and fat-soluble vitamins (FSV) using combinations of methanol, hexane, ethyl acetate, and acidified solvents. Final extracts diluted and filtered prior to analysis.
  • Chromatography: Raptor Biphenyl column (100×2.1 mm, 2.7 μm) with gradient elution of supercritical CO₂ and methanol (0.1% ammonium formate), total run time 6.5 min.
  • Detection: Electrospray ionization in positive mode, multi-reaction monitoring (MRM) with three transitions per analyte for quantitation and confirmation.

Used Instrumentation


  • Nexera UC SFC system.
  • Shimadzu LCMS-8050 triple quadrupole mass spectrometer.

Key Results and Discussion


  • Achieved simultaneous baseline separation of 17 vitamins in 6.5 min.
  • Limits of quantitation ranged from 0.05 to 13.5 ng/mL in matrix with linearity (R² ≥ 0.996) over relevant concentration ranges.
  • Extraction recoveries in fish matrix between 52.9% and 134.3%; matrix effects evaluated, with strong enhancement for vitamin B1 and suppression for several fat-soluble vitamins.
  • Repeatability (RSD) below 20% for most vitamins at 50 ng/mL, except vitamin K2 (~22%).
  • Application to non-spiked seabass detected vitamins B1, B5, B6, B3 acid, B3 amide, E, and E acetate with concentrations from 0.004 to 12.7 μg/g.

Benefits and Practical Applications


This rapid SFC-MS/MS method streamlines vitamin profiling in fish, reducing analysis time and solvent consumption. It supports food industry QA/QC, nutritional research, and regulatory monitoring of dietary supplements and aquaculture products.

Future Trends and Potential Applications


  • Expansion to other food matrices and complex biological samples.
  • Integration with high-throughput screening for nutritional databases.
  • Adaptation to emerging vitamins and metabolites using advanced SFC stationary phases.

Conclusion


A robust, high-speed SFC-MS/MS technique has been established for comprehensive analysis of water- and fat-soluble vitamins in fish. The method exhibits strong performance in terms of sensitivity, reproducibility, and matrix handling, offering a valuable tool for nutritional and quality control laboratories.

References


  • Taguchi K, Bamba T, Fukusaki E. Journal of Chromatography A. 2014;1362:270–277.
  • DeSimone JM. Science. 2002;297:799–803.
  • Lesellier E. Journal of Chromatography A. 2009;1216:1881–1890.
  • Murray J, Burt JR. The Composition of Fish. FAO. 2003.
  • Lee JX, Jumhawan U, Cao Y, Xing J, Zhan Z. ASMS 2017;Poster WP187.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Simultaneous Analysis of Water-soluble and Fat-soluble Vitamins in Fish by Reversed-Phase LC-MS/MS Method
HPLC Assay of Water-Soluble Vitamins, Fat-Soluble Vitamins, and a Preservative in Dry Syrup Multivitamin Formulation
Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC
Simultaneous determination of water- and fat-soluble vitamins in tablets and energy drinks by using a novel Vanquish Flex Duo system for Dual LC