Comprehending COVID-19: LC-MS/MS Analysis of Small Molecule Anti-Viral and Anti-Inflammatory Drugs in Plasma in Clinical Research

Applications | 2020 | WatersInstrumentation
LC/MS, LC/MS/MS, LC/QQQ
Industries
Clinical Research
Manufacturer
Waters

Significance of the topic


Clinical research into repurposed small-molecule antivirals and anti-inflammatory agents requires robust quantification in plasma for pharmacokinetic and pharmacodynamic studies, guiding therapeutic strategies and ensuring patient safety.

Objectives and study overview


This study aimed to develop and validate a rapid LC-MS/MS assay for simultaneous measurement of nine compounds in plasma: favipiravir, remdesivir, GS-441524, chloroquine, hydroxychloroquine, desethylchloroquine, lopinavir, ritonavir, and dexamethasone.

Methodology


A 50 µL plasma sample underwent protein precipitation with ZnSO4/methanol containing internal standards. After centrifugation, the supernatant was diluted and injected (15 µL) onto an ACQUITY UPLC I-Class system fitted with a CORTECS T3 (2.1 x 50 mm, 2.7 µm) column at 45 °C. Gradient elution employed ammonium formate/formic acid in water (mobile phase A) and methanol (mobile phase B) over a 3.3-minute run. Detection used a Xevo TQ-S micro mass spectrometer in ESI+ MRM mode. Data processing utilized MassLynx v4.2 and TargetLynx XS.

Used instrumentation


  • ACQUITY UPLC I-Class PLUS System
  • Xevo TQ-S micro Triple Quadrupole MS
  • CORTECS T3, 2.1 mm x 50 mm, 2.7 µm column
  • MassLynx v4.2 with TargetLynx XS

Main results and discussion


The method showed linear calibration (r2 > 0.995) and high sensitivity (S/N >25:1 at the lowest calibrator). Precision (≤9.1%) and accuracy (94–108%) were maintained over low, mid, and high QC levels across five days. Room temperature stability was limited for remdesivir, while freeze-thaw and autosampler stability (124 hours at 8 °C) were acceptable. Matrix effects were mitigated by internal standards, and extraction efficiencies were reproducible, although non-polar analytes exhibited lower recovery.

Benefits and practical application


  • High-throughput sample preparation suitable for large clinical studies
  • Simultaneous quantitation of multiple COVID-19 drug candidates in a single short run
  • Robust sensitivity and wide dynamic range to support dose-escalation and PK/PD profiling

Future trends and opportunities


Further work may focus on quantifying phosphorylated metabolites of nucleoside analogues within PBMCs, addressing analytical challenges via metal chelators or high-performance surface (HPS) technologies. Expansion to new antiviral classes and incorporation of automated sample preparation will enhance throughput and data reliability.

Conclusion


A rapid, robust LC-MS/MS assay has been established for nine therapeutic agents in plasma, offering a reliable tool for clinical research on COVID-19 treatments. Its performance characteristics support accurate PK/PD evaluation, guiding repurposing efforts and future antiviral development.

References


  • FDA. Bioanalytical Method Validation Guidance for Industry, 2018.
  • Avantaneo V. et al. Development and Validation of a UHPLC-MS/MS Method for Quantification of Remdesivir and GS-441524. J Antimicrob Chemother. 2020;75(7):1772–1777.
  • Warren TK. et al. Therapeutic Efficacy of GS-5734 Against Ebola Virus in Rhesus Monkeys. Nature. 2016;531:381–385.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Method for multiple COVID-19 drugs analysis by LC-MS/MS
A Simple LC-MS/MS Method for Simultaneous Analysis of 35 Anti-psychotics in Human Plasma for Clinical Research
Development of an Assay for the COVID-19 Drug Remdesivir- Toward Proper Remdesivir Use in Patients with Pre-Existing Conditions
A Simple LC-MS/MS Method for Simultaneous Analysis of 35 Anti-psychotics in Human Plasma for Clinical Research