The Markes TD-100™ is a high-throughput, fully automated thermal desorption system, designed to process up to 100 sample sorbent tubes in a single sequence.
It offers unparalleled efficiency and precision for laboratories analyzing volatile and semi-volatile organic compounds (VOCs and SVOCs). With its advanced features like robust automation, stringent leak testing, and customizable desorption options, the TD-100 ensures reliability and sensitivity for trace-level analyses.
The system's compatibility with wide-ranging volatility profiles and its innovative sample re-collection capabilities make it an ideal solution for high-demand applications, including environmental monitoring, industrial hygiene, and chemical research.
Technical Specifications of the Markes TD-100™
System Features
- Capacity: Supports up to 100 sorbent tubes for unattended operation.
- Volatility Range: Quantitative recovery of compounds across a wide volatility spectrum, including n-C40 and labile compounds such as mercaptans and amines.
- Cooling: Electrically cooled focusing trap for rapid, uniform temperature control.
- Carryover: <0.1% carryover to ensure high sensitivity across ppt to percent concentration ranges.
- Sample Tracking: Integrated TubeTAG technology for tracking tube history.
- Power Management: Extended standby mode reduces power consumption when not in use.
Sample Flow Path
- Temperature Control:
- Valve: 50–210 °C.
- Transfer Line: 50–225 °C.
- Adjustable in 1 °C increments for uniform heating.
- Materials: Inert components (PTFE, quartz, and coated stainless steel) ensure minimal sample adsorption.
Desorption Options
- Primary Tube Desorption Oven:
- Temperature Range: 35–425 °C, adjustable in 1 °C increments.
- Time Range: 0–999.9 minutes, with 0.1-minute resolution.
- Focusing Trap:
- Low Temperature: -30–50 °C.
- High Temperature: 35–425 °C.
- Uniform heating/cooling over the sorbent bed length.
- Backflush desorption for efficient sample recovery.
Pneumatics and Gas Requirements
- Carrier Gases: Compatible with helium, nitrogen, or hydrogen.
- Pressure Range: 0–60 psig for carrier and dry gases.
- Consumption: Typical carrier gas flow: 5–200 mL/min (method-dependent); dry gas flow: ~100 mL/min.
System Integration and Automation
- Sequencing: Automates up to 100 desorption steps with customizable methods for each tube.
- Split Control: Adjustable split ratios (0–125,000:1) with electronic mass flow controllers.
- SecureTD-Q™: Enables sample re-collection for repeat analysis or archival purposes.
Physical and Environmental Parameters
- Dimensions: Height: 62 cm; Width: 40 cm; Depth: 53 cm.
- Weight: 32 kg unloaded; 37 kg fully loaded.
- Operating Conditions: Temperature: 15–30 °C; Humidity: 5–95% RH (non-condensing).
Power and Data Connectivity
- Power Requirements: 100–240 V, 50/60 Hz, 650 W (self-adjusting).
- Data Interface: Includes GC interface cables for synchronization with GC systems and software.
The Markes TD-100™ combines advanced automation with precise control, delivering unmatched productivity and accuracy for high-throughput thermal desorption applications.