Agilent 1220 Infinity HPLC System (BP, ALS, TCC, VWD) , G4290B (Refurbished)

Agilent 1220 Infinity G4290B is a compact gradient HPLC system with binary pump, autosampler, column oven, and VWD, providing pressure up to 600 bar, flow to 10 mL/min, and UV detection from 190–600 nm.
Rental per month
600
€
without VAT
Purchase price
13,500
€
without VAT
In stock
+ 300 € delivery

Features

Condition:
Refurbished
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Application implementation
Extended warranty
Installation
Advanced training
Basic training

Features

Agilent 1220 Infinity HPLC System G4290B is a compact integrated analytical liquid chromatography system combining a gradient pump, automated sample injection, column temperature control, and variable-wavelength UV detection in a single instrument. The system provides pressures up to 600 bar, flow rates up to 10 mL/min, and is suitable for routine HPLC analysis, quality control, and chromatographic method development.

The offered configuration includes:

  • Gradient Pump – dual-channel low-pressure gradient formation
  • ALS – Autosampler
  • TCC – Column Oven
  • VWD – Variable Wavelength Detector

Gradient Pump

The Agilent 1220 Infinity gradient pump uses a serial dual-piston hydraulic design with a high-speed proportioning valve for low-pressure gradient formation.

The standard pump mixes two mobile phases to generate binary gradients.

Pump Technical Specifications
  • Hydraulic System: Dual plungers in series
  • Settable Flow Range: 0.001–10.000 mL/min
  • Recommended Flow Range: 0.2–10.0 mL/min
  • Maximum Pressure up to 5 mL/min: 600 bar
  • Maximum Pressure above 5 to 10 mL/min: 200 bar
  • Flow Precision: ≤0.07% RSD or <0.02 min SD
  • Flow Accuracy: ±1% or 10 µL/min, whichever is greater
  • Pressure Pulsation: <2%, typically <1.3%
  • Recommended pH Range: 1.0–12.5
  • Gradient Formation: Low-pressure binary mixing
  • Gradient Delay Volume: approximately 600–900 µL
  • Composition Range: 0–95% or 5–100%
  • Composition Precision: <0.2% RSD or <0.4 min SD
  • Compressibility Compensation: User selectable
Mobile Phases

The standard gradient configuration uses:

  • solvent A
  • solvent B

An optional solvent selection valve can increase the number of available solvents and provide additional method-development flexibility.

Integrated Degassing

The 1220 Infinity gradient configuration incorporates mobile-phase vacuum degassing.

Degassing helps:

  • reduce bubble formation,
  • stabilize pump operation,
  • improve gradient reproducibility,
  • reduce detector baseline disturbance.

ALS – Autosampler

Autosampler Technical Specifications
  • Injection Range: 0.1–100 µL
  • Increment: 0.1 µL
  • Multiple-Draw Extension: up to 1500 µL with hardware modification
  • Maximum Pressure: 600 bar
  • Replicate Injections per Vial: 1–99
  • Injection Precision, 5–100 µL: <0.25% RSD
  • Injection Precision, 1–5 µL: <1% RSD
  • Carryover: typically <0.1%
  • Carryover with External Needle Cleaning: typically <0.05%
  • Sample Viscosity Range: 0.2–50 cP
  • Typical Injection Cycle: approximately 50 s
Sample Capacity

The standard tray accommodates:

  • 100 × 2 mL vials

Alternative half-trays support:

  • 40 × 2 mL vials
  • 15 × 6 mL vials

TCC – Column Oven

The integrated column oven provides stable chromatographic column temperature for improved retention-time reproducibility and separation selectivity.

Column Oven Technical Specifications
  • Temperature Range: from 5 °C above ambient
  • Maximum Temperature: 80 °C with corresponding firmware
  • Temperature Stability: ±0.15 °C
  • Temperature Accuracy: ±0.8 °C
  • Column Capacity: one column up to 25 cm
  • Internal Volume: approximately 6 µL

The oven does not actively cool below ambient temperature.

VWD – Variable Wavelength Detector

The Agilent 1220 Infinity VWD is a double-beam UV photometer using a deuterium lamp. It provides selectable UV detection over the 190–600 nm wavelength range and is designed primarily for routine quantitative HPLC analysis.

VWD Technical Specifications
  • Detector Type: Double-beam photometer
  • Light Source: Deuterium lamp
  • Wavelength Range: 190–600 nm
  • Wavelength Accuracy: ±1 nm
  • Spectral Bandwidth: typically 6.5 nm
  • Maximum Data Rate: 80 Hz
  • Short-Term Noise: <±0.25 × 10⁻⁵ AU at 230 nm
  • Drift: <1 × 10⁻⁴ AU/h at 230 nm
  • Linear Absorbance Range: >2 AU
Standard Flow Cell

The standard VWD cell provides:

  • Volume: 14 µL
  • Path Length: 10 mm
  • Maximum Pressure: 40 bar

Other available cells included:

  • high-pressure cell – 14 µL / 10 mm / 400 bar
  • micro cell – 1 µL / 5 mm
  • semi-micro cell – 5 µL / 6 mm

The exact flow cell installed in the offered instrument should be confirmed from the cell PN.

Overall System Performance

The G4290B is designed for analytical HPLC and faster separations using columns with smaller particles.

Pressure Capability
  • up to 600 bar at flow rates up to 5 mL/min
  • up to 200 bar above 5 to 10 mL/min

The 600 bar pressure capability allows use of selected columns packed with particles around 2.7 µm for faster HPLC separations.

Compact Integrated Design

Unlike modular 1200 or 1260 Infinity systems, the principal 1220 Infinity components are installed within a common chassis.

This provides:

  • reduced bench-space requirements,
  • shorter capillary connections,
  • simplified installation,
  • convenient service access,
  • integrated system control.

Physical Specifications

  • Width: 370 mm
  • Depth: 420 mm
  • Height: 640 mm
  • Weight: approximately 30 kg
  • Line Voltage: 100–240 VAC, ±10%
  • Line Frequency: 50/60 Hz
  • Maximum Power Consumption: approximately 210 W
  • Ambient Operating Temperature: 4–55 °C
  • Maximum Operating Altitude: 2000 m

Software and Communication

Depending on configuration, the 1220 Infinity can be controlled using:

  • Agilent ChemStation
  • Agilent OpenLab CDS
  • Agilent EZChrom
  • Agilent Lab Advisor / Instrument Utilities

Communication interfaces include:

  • LAN
  • CAN
  • RS-232C
  • APG Remote

Typical Applications

  • Routine analytical HPLC
  • Pharmaceutical quality control
  • Active ingredient and impurity analysis
  • Food analysis
  • Environmental analysis
  • Cosmetic-product analysis
  • Chemical analysis
  • HPLC method development and validation
  • QA/QC laboratories
  • Fast gradient HPLC methods