Agilent 1260 Infinity GPC/SEC Multi Detector Suite (RI, Bio-LS), G7800A (Refurbished)

Agilent G7800A 1260 Infinity GPC/SEC Multi-Detector Suite configured with RI and Bio-Dual Angle LS/DLS provides concentration, absolute molecular weight, and hydrodynamic radius measurements from approximately 1–1000 nm.
Rental per month
1,200
€
without VAT
Purchase price
29,000
€
without VAT
In stock
+ 300 € delivery

Features

Condition:
Refurbished
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Installation
Basic training
Extended warranty

Features

Agilent 1260 Infinity GPC/SEC Multi-Detector Suite G7800A is a modular multidetector platform for gel permeation and size exclusion chromatography (GPC/SEC). The offered configuration combines differential refractive index (RI) detection with a Bio-Dual Angle Light Scattering / Dynamic Light Scattering detector (LS/DLS), providing simultaneous information on sample concentration, absolute molecular weight, light scattering, and hydrodynamic molecular size in solution.

Offered Configuration

  • G7800A – 1260 Infinity GPC/SEC Multi-Detector Suite, dual-compartment configuration
  • G7801A – Refractive Index Detector
  • G7809A – Bio-Dual Angle LS / DLS Detector
  • Integrated control module for detector operation and data acquisition

The detector modules on the offered unit are labeled 1260 Infinity II RI Detector and 1260 Infinity II Bio-Dual Angle LS / DLS.

Refractive Index Detector

The RI detector acts as a universal concentration detector for GPC/SEC.

It measures the difference in refractive index between pure mobile phase and the eluting sample. Because most polymers and macromolecules produce a refractive-index response, RI detection can also be used for compounds without a suitable UV chromophore.

RI data can provide:

  • concentration of the eluting polymer,
  • conventional GPC chromatographic response,
  • molecular-weight distribution through conventional calibration,
  • concentration information required for light-scattering calculations.
RI Detector Technical Specifications
  • Detection Principle: Differential refractive index
  • Detection Type: Deflection
  • Wavelength: 658 nm
  • Flow Cell Volume: 6 µL
  • Short-Term Noise: <80 µV
  • Flow Cell Pressure Rating: 350 kPa / 50 psi
  • Temperature Range: 30–60 °C
  • Temperature Stability: ±0.2 °C
  • pH Range: 2–10
  • Wetted Materials: 316 stainless steel, quartz
  • Purge Port: Yes

The low flow-cell volume helps minimize chromatographic band broadening during multidetector GPC/SEC analysis.

Bio-Dual Angle Light Scattering Detector

The dual-angle static light scattering detector measures light scattered by molecules in solution at two angles:

  • 15° – low angle
  • 90° – high angle

Static light scattering provides molecular-weight information based on the physical properties of the eluting molecules rather than assigning molecular weight solely from retention time and a conventional calibration curve.

LS Technical Specifications
  • Detection Principle: Static light scattering
  • Scattering Angles: 15° and 90°
  • Laser Wavelength: 658 nm
  • Sample Cell Volume: 10 µL
  • Effective Scattering Volume: 0.01 µL
  • Temperature Range: 30–60 °C
  • Temperature Stability: ±0.2 °C
  • pH Range: 2–10

Dual-angle measurement is particularly valuable for high-molecular-weight species where angular dependence of the scattered light becomes significant.

Dynamic Light Scattering (DLS)

The same Bio-LS/DLS module also performs dynamic light scattering measurements.

DLS monitors time-dependent fluctuations in scattered-light intensity caused by Brownian motion of molecules or particles in solution.

These data are used to calculate the hydrodynamic radius Rh, describing the effective size of a molecule or particle in solution.

DLS Technical Specifications
  • Detection Principle: Dynamic Light Scattering
  • Measurement Angle: 90°
  • Laser Wavelength: 658 nm
  • Hydrodynamic Radius Range: 1–1000 nm
  • Flow Cell Volume: 10 µL
  • Effective Scattering Volume: 0.01 µL
  • Correlator: 512-channel multi-tau
  • Data Acquisition Time: 0.1–3600 s
  • Temperature Range: 30–60 °C
  • Temperature Stability: ±0.2 °C
  • pH Range: 2–10

DLS can be used for characterization of:

  • proteins,
  • aggregates,
  • polymeric macromolecules,
  • nanoparticles,
  • oligomers,
  • conformational changes.

Combined RI + LS/DLS Detection

The principal advantage of this configuration is the combination of independent information about the eluting sample.

RI Provides
  • concentration information,
  • conventional chromatographic profile,
  • concentration data required for LS molecular-weight calculations.
Static LS Provides
  • absolute molecular weight,
  • information about larger molecular structures,
  • aggregation and oligomer detection.
DLS Provides
  • hydrodynamic radius Rh,
  • molecular size in solution,
  • additional aggregation and conformation information.

Together, these signals provide substantially more characterization information than conventional RI-only GPC/SEC.

Absolute Molecular Weight

With light-scattering detection, molecular weight does not need to be assigned solely from retention time relative to calibration standards.

When sample concentration and the appropriate dn/dc value are known, the light-scattering signal can be used to determine absolute molecular weight.

This helps avoid errors caused by differences in hydrodynamic volume between the analyte and the polymer standards used for conventional column calibration.

Low-Dispersion Design

The Multi-Detector Suite is designed to minimize chromatographic band broadening.

  • RI cell: 6 µL
  • LS/DLS cell: 10 µL
  • Effective LS/DLS scattering volume: 0.01 µL

Low internal volume is particularly important when multiple detectors are connected in series.

Detector Temperature Control

Both detectors can be temperature controlled over:

  • 30–60 °C

Temperature stability is:

  • ±0.2 °C

Stable temperature is especially important for refractive-index detection because small temperature variations can alter refractive index and cause baseline drift.

Typical Applications

  • Polymer characterization
  • GPC/SEC
  • Protein SEC
  • Absolute molecular-weight determination
  • Molecular-weight distribution
  • Aggregate and oligomer characterization
  • Hydrodynamic-radius determination
  • Biopolymers
  • Proteins and monoclonal antibodies
  • Polysaccharides
  • Synthetic polymers
  • Macromolecule research in solution