Agilent 1200 HPLC system (QP, ALS, TCC, DAD) (Refurbished)

Agilent 1200 Series HPLC system with G1322A degasser, G1311A quaternary pump, G1329A autosampler, G1316A column compartment, and G1315D DAD. Flow up to 10 mL/min, pressure up to 400 bar, and 190–950 nm DAD detection.
Purchase price
22,000
€
without VAT
In stock
+ 300 € delivery

Features

Condition:
Refurbished
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Installation
Advanced training
Extended warranty
Basic training
Application implementation

Features

Agilent 1200 Series HPLC is a modular analytical liquid chromatography system. The configuration supports isocratic and quaternary-gradient separations, automated sample injection, column temperature control, and UV-Vis detection with spectral acquisition.

The system is suitable for routine analytical HPLC, method development and validation, quality control, and pharmaceutical, food, and environmental applications.

System Configuration

  • G1322A – Vacuum Degasser
  • G1311A – Quaternary Pump
  • G1329A – Autosampler (ALS)
  • G1316A – Thermostatted Column Compartment (TCC)
  • G1315D – Diode Array Detector (DAD)

G1322A Vacuum Degasser

Agilent G1322A is a four-channel vacuum degasser designed to remove dissolved gases from mobile phases before they enter the pump.

Degassing helps reduce:

  • bubble formation,
  • flow instability,
  • baseline fluctuations,
  • gradient formation problems.
G1322A Technical Specifications
  • Number of Channels: 4
  • Maximum Flow: 10 mL/min per channel
  • Typical Internal Volume: 12 mL per channel
  • Principle: Vacuum membrane degassing
  • pH Range: 1–14
  • Solvent-Contact Materials: PTFE, PEEK
  • Maximum Power Consumption: 30 W
  • Weight: approximately 7 kg

G1311A Quaternary Pump

Agilent G1311A is a quaternary HPLC pump using low-pressure proportioning of up to four mobile phases.

Its serial dual-piston design provides stable flow and reproducible gradient formation.

G1311A Technical Specifications
  • Type: Quaternary HPLC Pump
  • Solvent Channels: Up to 4
  • Settable Flow Range: 0.001–10.000 mL/min
  • Recommended Flow Range: 0.2–10.0 mL/min
  • Maximum Pressure up to 5 mL/min: 400 bar
  • Maximum Pressure above 5 to 10 mL/min: 200 bar
  • Flow Accuracy: ±1% or 10 µL/min, whichever is greater
  • Flow Precision: ≤0.07% RSD or ≤0.02 min SD
  • Composition Range: 0–95% or 5–100%
  • Composition Precision: <0.2% RSD
  • Gradient Delay Volume: approximately 800–1100 µL
  • Recommended pH Range: 1.0–12.5
  • Compressibility Compensation: User selectable
Quaternary Gradient

The G1311A uses a high-speed proportioning valve to form gradients on the low-pressure side of the pump.

The system supports:

  • isocratic methods,
  • binary gradients,
  • ternary gradients,
  • quaternary gradients.

G1329A Autosampler

Agilent G1329A ALS provides automated liquid sample injection into the HPLC system.

With the standard 100 µL metering head, the injection range is 0.1–100 µL.

G1329A Technical Specifications
  • Injection Range: 0.1–100 µL
  • Increment: 0.1 µL
  • Multiple-Draw Extension: up to 1500 µL with appropriate hardware modification
  • Maximum Pressure: 400 bar
  • Injection Precision: <0.25% RSD from 5–100 µL
  • Precision at 1–5 µL: <1% RSD
  • Carryover: typically <0.1%
  • Carryover with External Needle Cleaning: typically <0.05%
  • Replicate Injections per Vial: 1–99
  • Typical Injection Cycle: approximately 50 s
Sample Capacity

The standard tray accommodates:

  • 100 × 2 mL vials

Alternative half-trays support:

  • 40 × 2 mL vials
  • 15 × 6 mL vials

G1316A Thermostatted Column Compartment

Agilent G1316A TCC provides precise temperature control for HPLC columns.

Stable column temperature improves:

  • retention-time reproducibility,
  • separation stability,
  • selectivity,
  • method transferability.
G1316A Technical Specifications
  • Temperature Range: approximately 10 °C below ambient to 80 °C
  • Temperature Stability: ±0.15 °C
  • Temperature Accuracy after Calibration: ±0.8 °C
  • Column Capacity: Up to three 30 cm columns
  • Warm-Up from Ambient to 40 °C: approximately 5 min
  • Cool-Down from 40 to 20 °C: approximately 10 min
  • Left Heat Exchanger Volume: approximately 3 µL
  • Right Heat Exchanger Volume: approximately 6 µL

G1315D Diode Array Detector

Agilent G1315D DAD is a UV-Vis diode-array detector that supports simultaneous monitoring at multiple wavelengths and acquisition of complete UV-Vis spectra across chromatographic peaks.

The DAD can also be used for:

  • compound identity confirmation,
  • spectral comparison,
  • peak-purity assessment,
  • optimization of detection wavelength.
G1315D Technical Specifications
  • Detector Type: Diode Array
  • Photodiode Array: 1024 elements
  • Wavelength Range: 190–950 nm
  • Data Rate: up to 20 Hz
  • UV Light Source: Deuterium lamp
  • Visible Light Source: Tungsten lamp
  • Wavelength Accuracy: ±1 nm
  • Programmable Slit Width: 1, 2, 4, 8, or 16 nm
  • Diode Width: <1 nm
  • Linear Absorbance Range: >2 AU at 265 nm
  • Short-Term Noise: <±0.7 × 10⁻⁵ AU at 254 and 750 nm
  • Drift: <0.9 × 10⁻³ AU/h at 254 nm
DAD Flow Cells

The G1315D supports multiple flow-cell configurations.

A standard analytical flow cell provides:

  • Volume: 13 µL
  • Path Length: 10 mm
  • Maximum Pressure: 120 bar

Micro, semi-micro, nano, semi-nano, high-pressure, and preparative cells were also available.

The exact flow cell installed in the offered system should be verified directly on the detector.

Overall System Performance

In this configuration, system pressure is primarily limited by the G1311A pump and G1329A autosampler:

  • up to 400 bar at flow rates up to 5 mL/min
  • up to 200 bar at flow rates above 5 to 10 mL/min

The system is therefore intended for conventional analytical HPLC rather than modern 600–1300 bar UHPLC operation.

Control and Software

Depending on configuration, the Agilent 1200 Series can be controlled using software such as:

  • Agilent ChemStation
  • Agilent OpenLab CDS
  • other compatible chromatography data systems

The exact software, PC, and licenses should only be considered included if specifically listed with the offered system.

Typical Applications

  • Pharmaceutical analysis
  • Quality control
  • Active pharmaceutical ingredient and impurity analysis
  • Food analysis
  • Environmental analysis
  • Natural-product analysis
  • HPLC method development and validation
  • Routine laboratory analysis
  • UV-Vis spectral characterization of chromatographic peaks