Agilent 1100 series HPLC Degasser G1322A (Refurbished)

Agilent G1322A is a four-channel vacuum degasser for 1100 Series HPLC systems, providing up to 10 mL/min per channel, approximately 12 mL internal volume per channel, and a pH range of 1–14.
Purchase price
1,100
€
without VAT
In stock
+ 100 € delivery

Features

Condition:
Refurbished
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Installation
Extended warranty
Basic training

Features

Agilent G1322A is a four-channel vacuum degasser designed for Agilent 1100 Series HPLC systems. It removes dissolved gases from the mobile phase before they enter the pump, helping reduce bubble formation, flow instability, and baseline fluctuations.

Each of the four independent channels supports flow rates up to 10 mL/min and has a typical internal volume of approximately 12 mL. Its four-channel design makes the G1322A particularly suitable for binary and quaternary HPLC configurations using multiple solvents.

Degasser Function

Mobile phases can contain dissolved gases that may form bubbles as pressure changes or when different solvents are mixed.

These bubbles can affect:

  • flow stability,
  • pump operation,
  • gradient reproducibility,
  • detector baseline stability,
  • sensitivity of certain detectors.

The G1322A removes dissolved gases using a vacuum membrane system before the mobile phase reaches the HPLC pump.

Four-Channel Design

The degasser contains four independent channels.

This allows simultaneous degassing of up to four solvents, for example:

  • mobile phase A,
  • mobile phase B,
  • mobile phase C,
  • mobile phase D.

This configuration is especially useful for quaternary-gradient HPLC systems.

Each channel supports a maximum flow rate of 10 mL/min.

Vacuum Degassing

Mobile phase passes through membrane tubing located within a vacuum chamber.

Dissolved gases diffuse through the membrane into the reduced-pressure space and are removed by the vacuum pump.

This reduces dissolved-gas content without requiring external helium sparging or ultrasonic degassing.

Vacuum Operating Modes

The G1322A automatically regulates vacuum according to operating conditions.

Normal Operating Mode 1
  • approximately 115 Torr
  • vacuum pump cycles automatically according to vacuum level
Normal Operating Mode 2

If 115 Torr cannot be achieved, for example due to high flow rates or high dissolved-gas load:

  • operating range 115–190 Torr
  • vacuum pump operates for approximately 30 seconds every 2 minutes
Continuous Mode

For applications requiring maximum degassing efficiency:

  • vacuum below 115 Torr
  • vacuum pump runs continuously

This mode is particularly useful for highly sensitive applications such as refractive index detection.

Vacuum Monitoring

The G1322A incorporates a pressure sensor for monitoring the vacuum system.

The auxiliary analog output provides:

  • 0–3 V output range
  • signal corresponding to vacuum pressure within the chamber

If the required vacuum cannot be achieved, for example because of a leak, the degasser enters an error condition.

System Communication

Unlike most other Agilent 1100 Series modules, the G1322A is not connected through the CAN bus.

It can interface with the LC system through:

  • APG Remote
  • analog AUX output

In the event of a degasser fault, the remote interface can signal other modules to stop the system.

Compatibility

The G1322A is primarily intended for:

  • Agilent 1100 Series HPLC
  • isocratic HPLC pumps
  • binary HPLC pumps
  • quaternary HPLC pumps
  • modular LC systems requiring external mobile-phase degassing

The G1322A was also subsequently used as a standard external degasser in selected Agilent 1200 and 1260 Infinity configurations.

Technical Specifications

  • Product Family: Agilent 1100 Series
  • Degassing Principle: Vacuum membrane degassing
  • Number of Channels: 4
  • Maximum Flow Rate: 10 mL/min per channel
  • Typical Internal Volume: 12 mL per channel
  • pH Range: 1–14
  • Solvent-Contact Materials: PTFE, PEEK
  • Analog Output: 0–3 V, pressure monitoring
  • Normal Operating Vacuum: approximately 115 Torr
  • Alternative Operating Range: 115–190 Torr
  • Line Voltage: 100–120 V or 220–240 V AC, ±10%
  • Line Frequency: 50 or 60 Hz, ±5%
  • Maximum Power Consumption: 30 W
  • Ambient Operating Temperature: 0–55 °C
  • Relative Humidity: <95%, non-condensing
  • Dimensions (W × D × H): 345 × 435 × 80 mm
  • Weight: 7 kg
  • Communication: APG Remote, AUX