Agilent Movable Optics II Assy QQQ (Support), G6303-67116 (Tested)

Agilent G6303-67116 is a Movable Optics II Assembly for the ion optics of compatible Triple Quadrupole LC/MS systems, providing ion guidance and focusing within the QQQ analyzer.
Purchase price
12,500
€
without VAT
In stock
+ 200 € delivery

Features

Condition:
Tested
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Installation
Basic training
Extended warranty

Features

Agilent G6303-67116 is an original service ion-optics assembly identified as Movable Optics II Assembly QQQ, designed for compatible Agilent Triple Quadrupole LC/MS systems. The module forms part of the mass spectrometer's vacuum ion path and contributes to ion guidance, focusing, and transmission between individual sections of the QQQ analyzer.

Ion-Optics Function

Ion optics in a mass spectrometer provide controlled transport of ions between individual analyzer sections.

The assembly helps:

  • guide the ion beam,
  • focus ions,
  • minimize ion losses,
  • transfer ions correctly to downstream analyzer components,
  • maintain a stable ion trajectory.

Correct ion-optics operation is important for sensitivity, signal stability, and reproducible LC/MS/MS performance.

Role in Triple Quadrupole LC/MS

A triple-quadrupole analyzer contains several sequential functional sections, including:

  • ion optics,
  • first quadrupole Q1,
  • Q2 collision cell,
  • second quadrupole Q3,
  • detector.

The Movable Optics Assembly forms part of this ion path and helps transfer ions correctly between the functional analyzer sections.

Assembly Construction

The offered unit is a complete electromechanical assembly incorporating:

  • metal ion-optics electrodes,
  • electrical insulators,
  • contacts and wiring,
  • mechanical support structure,
  • vacuum-compatible components.

The individual parts are assembled and aligned by the manufacturer as a complete service module.

Movable Optics

The Movable Optics designation identifies a mechanically positionable section of the analyzer ion optics. Correct electrode positioning is important for maintaining ion-path geometry and efficient ion transmission.

Compatibility

G6303-67116 is intended for:

  • Agilent Triple Quadrupole LC/MS systems
  • QQQ analyzers using the corresponding G6303 ion-optics architecture

Compatibility should be confirmed before installation using the:

  • LC/TQ model,
  • instrument serial number,
  • hardware revision,
  • original installed assembly PN.

Different generations of Agilent Triple Quadrupole LC/MS systems can use different ion-optics assemblies.

Service Application

Movable Optics Assembly replacement may be required during service involving:

  • damaged ion optics,
  • contaminated or mechanically damaged assemblies,
  • ion-transmission problems,
  • reduced sensitivity,
  • unstable response,
  • vacuum-analyzer repair,
  • LC/TQ system refurbishment.

Installation is intended for qualified service personnel.