Out of stock

Agilent 6460C LC/QQQ System with 1290 Infinity II UHPLC – G7120A, G7167B, G7116B (Refurbished)

The Agilent 6460C LC/QQQ with 1290 Infinity II G7120A, G7167B, and G7116B modules provides a complete UHPLC-MS/MS platform for highly selective targeted quantitation. It combines an m/z 5–3000 triple-quadrupole mass analyzer with 1300 bar binary UHPLC, high-capacity automated sample handling, and precise dual-zone column temperature control.
Purchase price
115,000
without VAT
Out of stock
+ 700  delivery

Features

Condition:
Refurbished
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Installation
Advanced training
Extended warranty
Basic training
Application implementation

Features

The Agilent 6460C LC/QQQ is a sensitive triple quadrupole tandem mass spectrometer designed primarily for targeted quantitative LC/MS/MS analysis. The offered configuration combines the 6460C with an Agilent 1290 Infinity II UHPLC system consisting of a G7120A High Speed Pump, G7167B Multisampler, and G7116B Multicolumn Thermostat. Together, these modules provide rapid gradient separations, operation up to 1300 bar, automated high-capacity sample handling, and precise column temperature control in a fully integrated LC/QQQ workflow.

Offered Configuration

  • G6460C: Agilent 6460 Triple Quadrupole LC/MS
  • G7120A: Agilent 1290 Infinity II High Speed Pump
  • G7167B: Agilent 1290 Infinity II Multisampler
  • G7116B: Agilent 1290 Infinity II Multicolumn Thermostat

Agilent 6460C Triple Quadrupole LC/MS

  • Mass Range: m/z 5–3000
  • Maximum Scan Rate: 12,500 Da/s
  • Polarity Switching: 30 ms
  • Autotune Resolution: 0.7 Da FWHM
  • Manual Resolution: 0.5 Da FWHM
  • Mass Accuracy:
    • 0.1 Da from m/z 5–1000
    • 0.01% from m/z 1000–2000
    • 0.02% from m/z 2000–3000
  • Mass Stability: <0.1 Da over 24 h
  • Detector Dynamic Range: >6 × 10⁶
  • Minimum MRM Dwell Time: 1 ms
  • MRM Transitions: up to 450 per time segment
  • Dynamic MRM: up to 4000 transitions per method
  • Triggered MRM: up to 10 transitions per compound
  • Collision Cell Clearance: <1 ms 
Supported acquisition modes include:
  • MS Scan
  • Product Ion Scan
  • MRM
  • Dynamic MRM
  • Triggered MRM
  • Precursor Ion Scan
  • Neutral Loss/Gain Scan
  • SIM

G7120A – 1290 Infinity II High Speed Pump

  • Binary high-pressure gradient pump
  • Settable Flow Range: 0.001–5.0 mL/min
  • Recommended Flow Range: 0.05–5.0 mL/min
  • Maximum Pressure: 1300 bar
  • Flow Precision: ≤0.07% RSD or 0.005 min SD
  • Pump Resolution: 300 pL
  • Delay Volume: down to approximately 10 µL
  • Integrated degasser
  • Active seal wash
  • Jet Weaver mixer
  • Active pressure damping
  • ISET method-emulation capability 

G7167B – 1290 Infinity II Multisampler

  • Maximum Pressure: 1300 bar
  • Standard Injection Range: 0.1–20 µL
  • Optional Injection Range: 40 or 100 µL
  • Multi-Draw: up to 1500 µL depending on configuration
  • Injection Precision: <0.15% RSD or SD <10 nL
  • Injection Linearity: 0.9999 from 0.1–100 µL
  • Sample Viscosity: 0.2–5.0 cP
  • Maximum Capacity:
    • up to 6144 samples in 384-well format
    • up to 1536 samples in 96-well format
  • Vials, Eppendorf tubes, and deep-well plates supported
  • Internal and external needle wash
  • Needle-seat backflush capability
  • Optimized for very low carryover 

G7116B – 1290 Infinity II Multicolumn Thermostat

  • Two independent Peltier-controlled zones
  • Temperature Range:
    • up to 20 °C below ambient
    • minimum 4 °C
    • maximum 110 °C
  • Temperature Setting Resolution: 0.1 °C
  • Temperature Stability: ±0.03 °C
  • Temperature Accuracy: ±0.5 °C after calibration at 40 °C
  • Temperature Precision: 0.05 °C
  • Column Capacity:
    • up to 8 × 100 mm columns
    • or 4 × 300 mm columns
  • Optional automated eight-column selection
  • High-pressure valve options up to 1300 bar 

Typical Applications

  • Targeted quantitative LC/MS/MS
  • Pharmaceutical analysis
  • Bioanalysis and DMPK
  • Drug and metabolite quantitation
  • Forensic toxicology
  • Clinical research
  • Pesticide and residue analysis
  • Mycotoxins
  • Veterinary drugs
  • PFAS and environmental contaminants
  • Food analysis
  • Trace analysis in complex matrices
  • Multi-residue screening
  • Dynamic MRM workflows