Agilent 1260 Infinity HPLC system (QP, TH+ALS, TCC, DAD) (Refurbished)

This Agilent 1260 Infinity HPLC configuration combines quaternary solvent delivery, automated temperature-controlled sample handling, precise column thermostating, and fast diode-array detection in one modular system. With up to 600 bar pump pressure and 190–640 nm spectral acquisition, it provides a versatile platform for routine analytical HPLC.
Purchase price
31,500
without VAT
In stock
+ 300  delivery

Features

Condition:
Refurbished
Warranty:
3 months
Manufacture year:
0
Countries:
Czech Republic
Additional services
Installation
Advanced training
Extended warranty
Basic training
Application implementation

Features

This Agilent 1260 Infinity HPLC System is a complete modular liquid chromatography platform for routine and advanced analytical applications. The configuration combines a G1311B Quaternary Pump, G1329B Standard Autosampler with G1330B Thermostat, G1316A Thermostatted Column Compartment, and G4212B Diode Array Detector. Together, these modules provide flexible four-solvent gradient formation, automated and temperature-controlled sample handling, precise column temperature control, and simultaneous chromatographic and UV/Vis spectral detection.

System Components

G1311B – 1260 Infinity Quaternary Pump
  • Flow range: 0.2–10.0 mL/min
  • Settable flow: 0.001–10 mL/min
  • Pressure:
    • up to 600 bar at ≤5 mL/min
    • up to 200 bar above 5 to 10 mL/min
  • Flow accuracy: ±1% or 10 µL/min
  • Flow precision: ≤0.07% RSD
  • Low-pressure quaternary gradient formation
  • Up to four solvents
  • Delay volume: approximately 600–800 µL
  • Recommended pH range: 1.0–12.5
  • Solvent compressibility compensation
  • Early Maintenance Feedback 
G1329B – 1260 Infinity Standard Autosampler
  • Injection volume: 0.1–100 µL
  • Up to 1500 µL with Multi-Draw configuration
  • Maximum pressure: 600 bar
  • Capacity: 100 × 2 mL vials
  • Replicate injections: 1–99
  • Typical precision:
    • <0.25% RSD above 5 µL
    • <1% RSD from 1–5 µL
  • Carryover: typically <0.1%
  • With external needle wash: typically <0.05%
  • Sample viscosity: 0.2–50 cP 
G1330B – Autosampler Thermostat
  • Temperature setting: 4–40 °C
  • Cooling capability: approximately 10 °C below ambient
  • Dimensions: 140 × 345 × 435 mm
  • Power: 100–240 VAC
  • Maximum active power: approximately 210 W 
G1316A – Thermostatted Column Compartment
  • Temperature range: 10 °C below ambient to 80 °C
  • Stability: ±0.15 °C
  • Accuracy: ±0.8 °C, or ±0.5 °C after calibration
  • Capacity: up to three 300 mm columns
  • Heat-up to 40 °C: approximately 5 min
  • Cool-down 40 → 20 °C: approximately 10 min
  • Column identification support 
G4212B – 1260 Infinity Diode Array Detector
  • Detector: 1024-element diode array
  • Light source: Deuterium lamp
  • Wavelength range: 190–640 nm
  • Wavelength accuracy: ±1 nm
  • Simultaneous signals: 8
  • Maximum sampling rate: 80 Hz
  • Slit width: 4 nm
  • Spectral libraries and peak-purity analysis
  • Standard Max-Light cartridge cell:
    • 10 mm path length
    • approximately 1 µL σ dispersion volume 

Typical Applications

  • Routine HPLC analysis
  • Pharmaceutical quality control
  • Food and beverage analysis
  • Environmental testing
  • Chemical analysis
  • Method development and validation
  • UV/Vis spectral identification
  • Peak-purity assessment
  • Automated unattended sample sequences