Agilent Intuvo 9000 GC System, S/SL, FID, J&W DB-1 Intuvo GC Column, G3950A (Refurbished)

Agilent Intuvo 9000 GC with an S/SL inlet, FID detector, and J&W DB-1 column is a compact GC system combining direct column heating, precise control, and technologies for easy column replacement and protection.
Purchase price
9,500
without VAT
In stock
+ 200  delivery

Features

Condition:
Refurbished
Warranty:
6 months
Manufacture year:
2020
Countries:
Czech Republic
Additional services
Installation
Advanced training
Extended warranty
Basic training
Application implementation

Features

The Agilent Intuvo 9000 GC System with a split/splitless (S/SL) inlet and flame ionization detector (FID) is a modern gas chromatography platform developed for high analytical performance, precise chromatographic control, and simplified maintenance. The Intuvo system uses direct column heating rather than a conventional oven, allowing faster heating and cooling, more efficient analytical workflows, and reduced energy consumption.

The offered system is equipped with a split/splitless (S/SL) inlet with electronic pneumatic control (EPC), a flame ionization detector (FID), and an Agilent J&W DB-1 Intuvo GC column, 30 m × 0.250 mm × 0.25 µm.

Key Features

  • Split/splitless (S/SL) inlet with full electronic pneumatic control
  • Flame ionization detector (FID)
  • Agilent J&W DB-1 Intuvo GC column, 30 m × 0.250 mm × 0.25 µm
  • Expandable with TCD, ECD, NPD, FPD, SCD/NCD, or MS
  • Click-and-Run technology for rapid column replacement
  • Integrated Guard Chip for column protection
  • Smart ID Key for automatic column identification
  • Color touchscreen with built-in contextual help
  • Web interface for remote system monitoring
  • Automatic leak checking
  • Automatic compensation for ambient pressure and temperature changes
  • Pressure control resolution of 0.001 psi
  • Compact footprint requiring approximately half the bench space of a conventional GC

Configuration options

Technical Specifications:

Gas Chromatograph
  • Model: Agilent Intuvo 9000 GC
  • PN: G3950A
  • Direct-heating column architecture
  • Retention time repeatability: <0.008% or <0.0008 min
  • Peak area repeatability: <1% RSD
Installed Configuration
  • Inlet: split/splitless (S/SL)
  • Detector: flame ionization detector (FID)
  • Column: Agilent J&W DB-1 Intuvo GC
  • Column dimensions: 30 m × 0.250 mm × 0.25 µm
  • Column PN: 122-1032-INT
Supported Modules
  • Inlets: S/SL, MMI
  • Other supported detectors: TCD, ECD, NPD, FPD, SCD/NCD
  • Compatible with single and triple quadrupole GC/MS
  • Supports up to four detector signals
Chromatographic System
  • Up to two 30 m × 0.320 mm capillary columns or one 60 m × 0.320 mm column
  • Column IDs: 0.150–0.320 mm
  • Operating temperature: Ambient +10 °C to 450 °C
  • Temperature resolution: 0.1 °C
  • Up to 20 temperature ramps and 21 plateaus
  • Maximum heating rate: 250 °C/min
  • Cool-down from 450 °C to 50 °C in less than 3 minutes
  • Maximum run time: 999.99 minutes
Electronic Pneumatic Control (EPC)
  • Pressure resolution: 0.001 psi
  • Pressure setting increments: 0.001 psi from 0 to 99.999 psi; 0.01 psi from 100 to 150 psi
  • Pressure range: 0–100 or 0–150 psig, depending on configuration
  • Selectable units: psi, kPa, or bar
  • Constant pressure, pressure ramp, constant flow, and flow ramp modes
  • Automatic atmospheric pressure and temperature compensation
  • Automatic leak checking
  • Supports He, H₂, N₂, and Ar/CH₄ carrier gases
Split/Splitless Inlet
  • Maximum operating temperature: 400 °C
  • Split ratios up to 12,500:1
  • Splitless mode with pressure pulsing
  • Gas Saver mode
  • Electronic septum purge control
  • Total flow range:
    • 0–500 mL/min (N₂)
    • 0–1250 mL/min (He or H₂)
  • Turn-Top inlet sealing system
  • Optional inert inlet configuration