Determination of Chemical Mixtures in Environmental, Food, and Human Samples Using High-Resolution Mass Spectrometry-Based Suspect Screening Approaches
Suspect screening using LC- and GC-HRMS identified 547 chemicals across environmental, food, and human samples. Pharmaceuticals, pesticides, and personal care products were the most frequent contaminants.
The Chemical and Enantioselective Analysis of a New Essential Oil Produced by the Native Andean Species Aiouea dubia (Kunth) Mez from Ecuador
Essential oil from Aiouea dubia leaves was analyzed by GC–MS/FID and enantioselective GC. Major terpenes and chiral profiles suggest antibacterial and anti-inflammatory potential for cosmeceutical use.
Microwave-Assisted Digestion Method and Dispersive Magnetic Solid-Phase Microextraction for the Determination of Major and Trace Elements in Lignocellulosic Biomass by ICP-OES
This study introduces microwave-assisted digestion and dispersive magnetic SPE with ICP-OES to measure major and trace elements in lignocellulosic biomass with high accuracy and sensitivity.
Hydrophilic Interaction Chromatography HRMS with Acrylamide Monolithic Columns: A Novel Approach for Intact Antibody Glycoform Characterization
This study introduces acrylamide monolith HILIC-MS for intact mAb glycoprofiling, offering high selectivity, baseline separation, and detection of low-abundance glycoforms missed by RPLC-MS.
Ion-Pairing Hydrophilic Interaction Chromatography for Impurity Profiling of Therapeutic Phosphorothioated Oligonucleotides
Ion-pairing HILIC improves impurity profiling of therapeutic oligonucleotides. It resolves deaminated impurities from full-length products, beyond current LC-MS limits.
Global Careers in Liquid Chromatography: 20+ LC Jobs in Service, Sales & Research
Browse over 20 job offers in liquid chromatography from Waters, Agilent, Thermo, Shimadzu, Metrohm and others. Roles in sales, applications, service, and R&D.
Maturing conditions of bimetallic nanocomposites as a new factor influencing Au–Ag synergism and impact of Cu(II) and/or Fe(III) on luminescence
Gold–silver nanoclusters with fixed Au:Ag ratio were matured under different conditions. Fluorescence and synergism varied, with optimum at 37 °C, 2.5 h, and quenching by Cu(II)/Fe(III) was evaluated.
Global LCMS Conferences and Training 2025 – LabRulez
Explore global LCMS events in 2025: conferences, courses, workshops, and training. Stay updated on cutting-edge LC/MS methods and connect with experts worldwide.
Global GCMS Conferences and Training 2025 – LabRulez
Discover upcoming global GCMS events in 2025: conferences, schools, workshops, and training. Expand your knowledge and connect with the worldwide GC/MS community.